| 1. EKCO2 Series |
 |
NH3/CO2 brine unit
Refrigerant: NH3 Brine: CO2
CO2 brine temperature: -5℃ to -40℃
Uses: Freezing, refrigeration, low-temperature air-conditioning, showcase cooling, freezer cooling, etc.
Features:
1) Uses non-fluorocarbon NH3 as the primary refrigerant and CO2 as the brine.
2) Offers a 10% efficiency improvement over existing systems (Mayekawa data).
3) Requires no control of brine concentration or PH and the absence of corrosion reduces maintenance cost concerns.
|
 |
NH3/CO2 dual unit
Refrigerant: High side: NH3; Low side: CO2
CO2 evaporation temperature: -40℃ to -55℃
Uses: Freezers, ultra-low temperature warehouses, vacuum freezing systems
Features:
1) Uses non-fluorocarbon NH3 for the high side and CO2 for the low side.
2) Offers a 30% efficiency improvement over existing systems (Mayekawa data).
3) The high efficiency of this unit is achieved through use of a proprietary CO2 high-pressure freezer unit.
|
| 2. EK Series |
 |
Water-cooled EK Series, evaporator-condenser EK Series
Refrigerant: NH3 Brine: Nybrine Z-1, Etabrine
Brine outlet temperature:
Low temperatures of -28℃ to -36℃
High temperature: -3℃ to -14℃ (-18℃ for evaporator-condenser)
Uses: Industrial plant brine cooling systems, food chilling systems
Features:
1) Significantly less refrigerant is required (just 1/50 that of conventional systems (Mayekawa data).
2) Use of brine as the secondary refrigerant ensures safety for both humans and the products being chilled.
3) Use of Mayekawa’s unique compatible oil and electronic control expansion valve provides even higher efficiency.
|
|
3. MDC Series |
 |
MDC reciprocating and compact screw series
Refrigerant: NH3
Brine: Nybrine Z-1, Etabrine
Brine outlet temperature: 0℃ to -30℃
Uses: Industrial plant cooling systems, food chilling systems
Features:
1) Significantly less refrigerant required (just 1/50 that of conventional systems (Mayekawa data).
2) Use of brine as the secondary refrigerant ensures safety for both humans and the products being chilled.
3) High-performance plate heat exchangers are used in the evaporator and condenser, reducing installation dimensions .
4) Use of Mayekawa’s unique compatible refrigerator oil and electronic control expansion valve enables ammonia direct expansion and fully-automatic operation.
|
| 4. MNDC Series |
 |
MNDC Series brine chiller unit
Refrigerant: NH3
Uses: Beverage and dairy industry process chilling, food chilling systems
Features:
1) Refrigerant volume is reduced to just 0.2 kg per USRT.
2) High-performance plate heat exchangers are used in the evaporator and condenser, reducing installation dimensions .
3) Allows operation with cooling water at a temperatures of 1°C, facilitating low-temperature heat storage.
4) Allows brine operation. Ideal for use as a brine chiller for ice thermal storage.
|
|
|
CRW/MHS/MDF Series R404A compatible water-cooled condensing units |
 |
Refrigerant: R404A
Uses: Ice-making, ice banks, beverage and dairy industry process chilling, food chilling systems, refrigerators, freezers
Features:
1) By international agreement, production of the specified R22 fluorocarbon is to be significantly reduced from the year 2010. These systems are ideal for clients who wish to continue using fluorocarbon refrigerants for the time being.
2) A wide range of variations is available to suit all needs.
|
| |
Series type |
Operating temperature range (℃) |
| High-temperature range |
CRW |
0 to -30 |
| MDF high-temperature |
-10 to -35 |
| Low-temperature range |
MHS |
-35 to -70 |
| MDF low-temperature |
-35 to -70 |
|